Pentanol, 2- Chemical Storage Specifications

Compliant storage and rental solutions for Pentanol, 2- (C5H12O). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Pentanol, 2-

2-Pentanol (IUPAC name: pentan-2-ol; also called sec-amyl alcohol) is an organic chemical compound. It is used as a solvent and an intermediate in the manufacturing of other chemicals. 2-Pentanol is a component of many mixtures of amyl alcohols sold industrially.

Structured hazard data

Hazard class
Flammable Liquids Category 2
Storage category
Flammable Storage
Flammable
Yes
Flash point
34 °C / 93.2 °F
Storage temperature
below +30°C
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Incompatible Materials. Metals. Oxidizing agent.

Acute Inhalation Toxicity - Vapors Category 4 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system.

Fire Suppression System

Dry Chemical fire suppression is recommended for Pentanol, 2-

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Pentanol, 2- (C5H12O). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam. Water mist maybe used to cool closed containers.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Pentanol, 2- should account for its listed hazards (Flammable Liquids Category 2), climate control needs (below +30°C), and segregation requirements. Incompatible Materials. Metals. Oxidizing agent.

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Physical State Liquid Appearance Colorless Odor Characteristic Odor Threshold No information available pH No information available Melting Point/Range -50 °C / -58 °F Boiling Point/Range 118 - 119 °C / 244.4 - 246.2 °F Flash Point 34 °C / 93.2 °F Evaporation Rate No information available Flammability (solid,gas) Not applicable Flammability or explosive limits Upper 8.0% Lower 1.2% Vapor Pressure 3 mbar @ 20 °C Vapor Density 3.0 (Air = 1.0) Specific Gravity 0.812 Solubility Soluble in water Partition coefficient; n-octanol/water No data available Autoignition Temperature 340 °C / 644 °F Decomposition Temperature No information available Viscosity 4.1 mPa.s @ 20 °C Molecular Formula C5 H12 O Molecular Weight 88.15

Matched to this chemical

Recommended storage solutions for Pentanol, 2-

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Pentanol, 2- be stored?

Store Pentanol, 2- in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Flammable Liquids Category 2). Climate range guidance: below +30°C. Compatibility notes: Incompatible Materials. Metals. Oxidizing agent. US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Pentanol, 2- flammable?

Yes — Pentanol, 2- is flagged as a flammable hazard in this database (Yes). Flash point: 34 °C / 93.2 °F. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Pentanol, 2-?

Pentanol, 2- is listed as: Flammable Liquids Category 2. Acute Inhalation Toxicity - Vapors Category 4 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system.

What fire suppression is recommended for Pentanol, 2-?

Dry Chemical fire suppression is generally recommended for Pentanol, 2- (C5H12O). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Pentanol, 2- storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Pentanol, 2-. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.